
Zeziphi iintlobo zebhetri yeLithium Ion ezisebenza ngokugqibeleleyo kuwe?
Ujonge kwiintlobo zebhetri ye-lithium ion kwaye uziva wonganyelwe yiyo yonke ijagoni yobugcisa. LCO, NMC, LFP, LTO - bathetha ntoni aba nobumba? Okubaluleke ngakumbi, yeyiphi engayi kuchitha ibhajethi yakho okanye ibeke izixhobo zakho emngciphekweni?
Imakethi yehlabathi yelithium{0}}yebhetri ye-ion ifikelelweI-USD 75.2 yeebhiliyoni ngo-2024kwaye ikhula e15.8% CAGRnge2034 (gminsights.com). Ngokukhula okugqabhukileyo kuza ukubhideka malunga nokuba yeyiphi ikhemistri yebhetri ehambelana neemfuno zakho.
Akukho nto yokuthengisa - iinyaniso ozidingayo ukuze wenze ukhetho olulumkileyo.
Ukuqonda Iindidi zeBattery zeLithium Ion: Iziseko
Iintlobo zebhetri ion lithiumziyahluka ikakhulu kwizinto zabo cathode. Cinga ngecathode njengobuntu bebhetri - imisela ukuxinana kwamandla, ukhuseleko, ubomi kunye neendleko.
Zonke iibhetri ze-lithium zisebenza ngendlela efanayo: i-lithium ion ihamba phakathi kwe-anode (icala elibi) kunye ne-cathode (icala elihle) ngexesha lokutshaja kunye nokukhupha. Kodwa izinto ze-cathode zitshintsha yonke into malunga nokusebenza.
IIintlobo zebhetri ze-lithium ion ezinkulu ezi-6ezongamele imarike zezi:
I-LCO(iLithium Cobalt oxide)
NMC(Nickel Manganese Cobalt)
LFP(iLithium Iron phosphate)
LTO(Lithium Titanate)
LMO(iLithium Manganese oxide)
I-NCA(Nickel Cobalt Aluminium)
Nganye inika usetyenziso olwahlukileyo olusekelwe kwinto oyibeka phambili: ukuxinana kwamandla, ukhuseleko, ixabiso, okanye ubomi.
Uluhlu olupheleleyo: Iintlobo zebhetri ze-Lithium Ion ezi-6 ezibekwe ngokuSebenza
1. ILithium Iron Phosphate (LFP) - Intshatsheli yoKhuseleko
I-Voltage:3.2V igama
Ukuxinana kwamandla:90-205 Wh / kg
Ubomi bebhayisikile:Imijikelo eyi-1,000-9,000
Uluhlu lweendleko:$ 100-150 / kWh
Iibhetri ze-LFP ziphumelela kukhuseleko kunye nokuphila ixesha elide. Azinayo icobalt, izenzauzinzile kwaye ungabizi kakhulukunecobalt{0}esekwe kwezinye iindlela.
Igqibelele:Ukugcinwa kwamandla elanga, iibhasi zombane, iinkqubo zamandla ezigcinayo, izicelo zaselwandle
Kutheni ukhetha i-LFP:
Ubushushu be-Thermal bubaleka kwi-270 degreevs 150℃for LCO (greencubes.com)
Inokuphathaukukhupha imisinga ukuya kuthi ga kwi-20C
Isebenza kumaqondo obushushu agqithisileyo (-20℃ukuya kuma-60 degrees)
Akukho mngcipheko womlilonaxa igqojozwe okanye yonakele
Iingxaki:
Ukuxinana kwamandla asezantsi kuthetha ukuba iibhetri ezinkulu, ezinzima
Iphezulu kancinci{0}}inqanaba lokuzikhupha
2. I-Nickel Manganese Cobalt (NMC) - I-Balanced Performer
I-Voltage:3.6V igama
Ukuxinana kwamandla:150-220 Wh / kg
Ubomi bebhayisikile:1,000-2,000 imijikelo
Uluhlu lweendleko:$ 120-180 / kWh
Iibhetri ze-NMC zibonelela ngebhalansi engcono yoxinano lwamandla, ukhuseleko, kunye neendleko. II-NMC 811ukwahluka (iindawo ezisi-8 zenikeli, inxalenye e-1 yemanganese, inxalenye e-1 ye-cobalt) ibonelela ngamandla amakhulu oxinaniso kodwa ubomi bufutshane.
Igqibelele:Izithuthi zombane, -iibhayisekile, izixhobo zombane, ugcino lwegridi
Kutheni ukhetha i-NMC:
Ukuxinana kwamandla aphezulukwizicelo ezihlangeneyo
Ukuzinza okuhle kwe-thermal kunye nolawulo olufanelekileyo
Ikhemistri eguquguqukayo- inokuthungelwa amandla okanye amandla
Izibamboukutshaja imisinga ukuya kuthi ga kwi-2C
Iingxaki:
Iqulethe i-cobalt (iinkxalabo zokuziphatha kunye neendleko)
Ifuna iinkqubo zolawulo lwebhetri eziphucukileyo
Ukusebenza kunciphisa kumaqondo aphezulu
3. I-Lithium Cobalt Oxide (LCO) - I-Energy Dense Option
I-Voltage:3.6V igama
Ukuxinana kwamandla:150-200 Wh / kg
Ubomi bebhayisikile:500-1,000 imijikelo
Uluhlu lweendleko:$ 150-200 / kWh
Iibhetri ze-LCO zipakisha awona mandla kweyona ndawo incinci, zizenza zigqibelele kwizinto zombane eziphathwayo apho ubukhulu kunye nobunzima bubaluleke kakhulu.
Igqibelele:Ii-smartphones, iilaptops, iitafile, iikhamera, iidrone
Kutheni ukhetha i-LCO:
Ubuninzi bamandla obuphezuluphakathi kweekhemistri eziqhelekileyo
Icwecwe kwaye ikhaphukhaphu
Itekhnoloji eqinisekisiweyo enemixokelelwane yobonelelo esekiweyo
Iingxaki:
Ukubaleka kwe-Thermal kwi-150℃nje(greencubes.com)
Ubomi bomjikelo omfutshane
Ayinakukwazi ukukhupha imisinga ephezulu yokukhupha
Iyabiza ngenxa yomxholo we-cobalt
4. ILithium Titanate (LTO) - INgcali yokuTshaja ngokukhawuleza{2}}
I-Voltage:2.4V igama
Ukuxinana kwamandla:50-110 Wh / kg
Ubomi bebhayisikile:3,000-30,000 imijikelo
Uluhlu lweendleko:$ 200-400 / kWh
Iibhetri ze-LTO zincama uxinaniso lwamandlaubomi obude obugqithisileyo kunye -ukutshaja okukhawulezayo. Bangahlawulisa ukuya kwi-80% umthamo kwimizuzu nje emi-6.
Igqibelele:Ukukhawuleza-izikhululo zokutshaja, ugcino lwegridi, iibhasi zombane, izicelo zomkhosi
Kutheni ukhetha i-LTO:
Ukutshaja okukhawulezayo-kakhulu(10C+ amaxabiso)
Ubomi bomjikelo ogqithisileyo- ukuya kuma-30,000 imijikelo
Isebenza kumaqondo obushushu ukusuka -30 degrees ukuya 55 degrees
Umngcipheko we-Zero wokubaleka kwe-thermal
Iingxaki:
Uxinzelelo lwamandla asezantsikuzo zonke iikhemistri ze-lithium
Ibiza kakhuluukhetho
Ifuna iiseli ezininzi zokugcina amandla afanayo
5. ILithium Manganese Oxide (LMO) - IFavorite yeSixhobo saMandla
I-Voltage:3.7V igama
Ukuxinana kwamandla:100-150 Wh / kg
Ubomi bebhayisikile:300-1,000 imijikelo
Uluhlu lweendleko:$ 100-140 / kWh
Iibhetri ze-LMO zigqwesa ekunikezeni iziqhushumbisi zamandla aphezulu, zizenza zilungele usetyenziso olufuna ukukhutshwa ngokukhawuleza kwamandla.
Igqibelele:Izixhobo zamandla, izixhobo zonyango, izithuthi ezixubileyo (ezihlala zixutywa ne-NMC)
Kutheni ukhetha i-LMO:
Amandla aphezulu amandlakwizicelo ezifunayo
Ukhuseleko olungcono kune-LCO
Ixabiso eliphantsi kunecobalt{0}esekwe kwiibhetri
Ukuzinza kakuhle kwe-thermal
Iingxaki:
Ubomi bomjikelo ophakathi
Uxinzelelo lwamandla asezantsi kune-NMC okanye i-LCO
Isoloko ifuna ukuxubana nezinye iikhemistri
6. I-Nickel Cobalt Aluminium (NCA) - Ephakamileyo{2}}Ukhetho lokuSebenza
I-Voltage:3.6V igama
Ukuxinana kwamandla:200-260 Wh / kg
Ubomi bebhayisikile:Imijikelo ye-1,000-1,500
Uluhlu lweendleko:$ 160-220 / kWh
Iibhetri zeNCA zibonelela ngeubuninzi bamandla obuphezulungelixa ugcina unikezelo lwamandla olulungileyo. UTesla usebenzisa i-NCA chemistry kwiimoto zabo ezininzi.
Igqibelele:{0}}Iimoto zombane ezisebenzayo, usetyenziso lwe-aerospace, ii-elektroniki ze-premium
Kutheni ukhetha i-NCA:
Ubuninzi bamandla obuphezuluekhoyo
Unikezelo lwamandla olulungileyo
Uluhlu olude lokuqhuba ii-EVs
Ingqinwe kwizicelo ezifunwayo
Iingxaki:
Ibiza kakhulungenxa yomxholo we-cobalt kunye ne-aluminium
Ifuna ulawulo lwebhetri oluphucukileyo
Uvakalelo kumaqondo obushushu aphezulu
Ababoneleli abancinci

5-Uthelekiso lweDimensional: Iintlobo zebhetri yeLithium Ion kwintloko{2}}ukuya-entloko
| Uhlobo Lwebhetri | Ukuxinana kwamandla | Ukukala koKhuseleko | Ubomi bomjikelo | Ixabiso leNqanaba | Eyona Isicelo |
|---|---|---|---|---|---|
| LFP | Phakathi (90-205 Wh/kg) | Egqwesileyo | Kugqwesileyo (1,000-9,000) | Phantsi | Ukugcinwa kwamandla, iibhasi |
| NMC | Phezulu (150-220 Wh/kg) | Kulungile | Kuhle (1,000-2,000) | Phakathi | Izithuthi zombane |
| I-LCO | Phezulu (150-200 Wh/kg) | Ubuhlwempu | Amahlwempu (500-1,000) | Phezulu | Ii-elektroniki zabathengi |
| LTO | Phantsi (50-110 Wh/kg) | Egqwesileyo | Kugqwesileyo (3,000-30,000) | Phezulu kakhulu | Ukutshaja ngokukhawuleza |
| LMO | Phakathi (100-150 Wh/kg) | Kulungile | Ilungile (300-1,000) | Phantsi | Izixhobo zamandla |
| I-NCA | Phezulu kakhulu (200-260 Wh/kg) | Mhle | Kuhle (1,000-1,500) | Phezulu kakhulu | -ezokugqibela EVs |
Uhlalutyo lweendleko: Amanani okwenyani kwiindidi zebhetri zeLithium Ion ezahlukeneyo
Ukuqonda ililonke ixabiso lobuniniikunceda wenze izigqibo ezikrelekrele. Nantsi indlela yokubala elona xabiso:
Ifomula yokubala ixabiso lebhetri
Iindleko zizonke=(IiNdleko zoKuqala + Iindleko zoTshintsho + Iindleko zokuSebenza) ÷ Amandla ewonke anikezelweyo
Umzekelo wokubala (LFP vs NMC):
Ibhetri yeLFP
Iindleko zokuqala: $150/kWh × 100 kWh=$15,000
Ubomi bomjikelo: Imijikelo engama-6,000
Amandla ewonke: 100 kWh × 6,000 imijikelo=600,000 kWh
Iindleko ngekWh nganye ezizisiweyo: $15,000 ÷ 600,{3}} **$0.025/kWh**
Ibhetri ye-NMC
Iindleko zokuqala: $150/kWh × 100 kWh=$15,000
Ubomi boMjikelo: Imijikelo ye-1,500
Amandla ewonke: 100 kWh × 1,500 imijikelo=150,000 kWh
Iindleko ngekWh nganye ezizisiweyo: $15,000 ÷ 150,{3}} **$0.10/kWh**
Iziphumo:I-LFP ihambisa amandla kwi4x ixabiso eliphantsikubomi bayo nangona iindleko ezifanayo zangaphambili.
Okwenyani-Ukwahlulwa kweXabiso leHlabathi ngokweSicelo
1. UGcino lwaMandla eSola (inkqubo ye-10 kWh)
LFP: $1,500 yokuqala, $0.025/kWh zisiwe
NMC: $1,500 yokuqala, $0.10/kWh inikezelwe
Ophumeleleyo:I-LFP igcina i-${0}} kubomi benkqubo
2. Isithuthi soMbane (75 kWh pack)
NMC: $11,250 yokuqala, 300-mayile uluhlu
LFP: $11,250 yokuqala, 250-mayile uluhlu
Ophumeleleyo:Kuxhomekeke kwiimfuno zoluhlu vs iindleko
3. Ii-Electronics zabathengi (ibhetri yefowuni eyi-50 Wh)
LCO: $7.50 yokuqala, 2-3 iminyaka yokuphila
LFP: $5.00 yokuqala, 5-7 iminyaka yokuphila
Ophumeleleyo:I-LFP yokuphila ixesha elide, i-LCO yobukhulu
Ukhuseleko Kuqala: Zeziphi Iindidi zebhetri yeLithium Ion eZikhuselekileyo?
Ukhuseleko alukho malunga nokuphepha imililo kuphela - olumalunga nayoukusebenza okuthembekileyo phantsi koxinzelelo. Nalu udidi lokhuseleko ukusuka kweyona ikhuselekileyo ukuya kweyona inobungozi:
iNqanaba loku-1 loKhuseleko: Ultra{1}}Ekhuselekile
I-LTO kunye ne-LFP- Ezi khemistri ziphantse akunakwenzeka ukwenza ukubaleka kwe-thermal. Naxa zigqobhoziwe, zifakwe ishaji eninzi, okanye zitshiswe kakhulu, aziyi kutsha.
Inqanaba lesi-2 loKhuseleko: Ikhuselekile ngokubanzi
I-NMC kunye ne-LMO- Ikhuselekile ngeenkqubo zolawulo lwebhetri olululo. Funa ukujongwa kweqondo lokushisa kunye nokulawulwa kwentlawulo / ukukhupha.
iNqanaba lesi-3 loKhuseleko: Lifuna uBulumko
I-NCA kunye ne-LCO- Umngcipheko ophezulu wokubaleka ngobushushu. Kufuneka iinkqubo zokhuseleko eziphucukileyo kunye nokuphathwa ngononophelo.
Imiba ePhambili yoKhuseleko emayiqwalaselwe
1. Ubushushu be-Thermal Runaway
I-LFP: i-270℃(greencubes.com)
I-LTO: Akukho ukubaleka kwe-thermal
I-NMC: i-210 degree
I-LCO: i-150℃(greencubes.com)
2. Ukunyamezela intlawulo engaphezulu
I-LFP: Egqwesileyo - inokusingatha umrhumo ogqithisileyo ngaphandle komonakalo
I-LTO: Igqwesile - ngokugqithisileyo ukunyamezela
I-NMC: Ilungile - nge-BMS efanelekileyo
LCO: Imbi - inobuntununtunu kwintlawulo egqithisileyo

Izicelo zoShishino: Apho Uhlobo ngalunye lwebhetri yeLithium Ion lugqwesileyo
Izithuthi zoMbane: Idabi le-NMC vs LFP
I-NMC yongamela ii-premium EVsngenxa yobuninzi bamandla. I-Tesla Model S isebenzisa i-NCA ye-400+ yoluhlu lweemayile. KodwaI-LFP iya isandakwii-EVs zohlahlo lwabiwo-mali kunye nezithuthi zorhwebo.
Isabelo seMarike kwii-EVs (2024)
I-NMC: 60% yemarike yebhetri ye-EV yehlabathi (marketsandmarkets.com)
LFP: 35% kwaye ikhula ngokukhawuleza
Ezinye iikhemistri: 5%
Kutheni utshintshela kwi-LFP?
Ukunciphisa iindleko:Iindleko ze-LFP zehla zaya kutsho ngaphantsi kweedola ezili-100/kWh e-China
Iinkxalabo zokhuseleko:Imililo emininzi yeprofayile ye-EV ephezulu ibandakanya iibhetri ze-NMC
Ubomi obude:Abaqhubi beeFleet bakhetha ubomi obude be-LFP
Ukugcinwa kwamandla: I-Domain ye-LFP
Igridi-isikali sogcino lwamandlazisebenzisa kakhulu iibhetri ze-LFP. Ukhuseleko lwekhemistri kunye nobomi obude buyenza iphelele kwizicelo eziluncedo.
Indawo yokuhlala yelangaikwathanda i-LFP:
Tesla Powerwall 3:Isebenzisa LFP chemistry
Iibhetri ze-Enphase IQ:I-LFP- isekwe
Generac PWRcell:Itekhnoloji ye-LFP
I-Electronics yabathengi: I-LCO iseMithetho
Nangona kukho iinkxalabo zokhuseleko,I-LCO ihlala ilawulakwii-smartphones kunye neelaptops kuba:
Imiqobo yobungakanani ifuna ubuninzi bamandla obuninzi
Izixhobo zitshintshwa rhoqo emva kweminyaka emi-2-3
Yakhelwe-kwiinkqubo zokhuseleko ithomalalisa umngcipheko
Isabelo semarike kubathengi be-elektroniki
I-LCO: I-70% yeebhetri ze-smartphone
I-NMC: 25% (ikhula kwizixhobo zeprimiyamu)
Okunye: 5%
Ukukhetha Uhlobo lwebhetri yeLithium Ion eLungileyo: Isakhelo seSigqibo
Inyathelo loku-1: Chaza izinto ezibalulekileyo kuwe
| Okubalulekileyo | I-Chemistry ecetyiswayo | Engcono Kwi | Urhwebo{0} lucimile |
|---|---|---|---|
| Ukuxinana kwamandla | I-NCA okanye i-LCO | Izixhobo eziphathwayo, ubude{0}}ii-EVs | Iindleko eziphezulu, iinkxalabo zokhuseleko |
| Ukhuseleko | LFP okanye LTO | Ukugcinwa kwamandla, iimoto zorhwebo | Ukuxinana kwamandla asezantsi, iindleko ezinokuthi zibe phezulu |
| Iindleko | LFP okanye LMO | Usetyenziso lwebhajethi,-ubeko oluphezulu | Isenokufuna iinkqubo zebhetri ezinkulu |
| Ubomi obude | LTO okanye LFP | Iziseko zophuhliso, izicelo zorhwebo | Iindleko eziphezulu zangaphambili okanye ukuxinana kwamandla aphantsi |
Inyathelo lesi-2: Qwalasela isicelo sakho
Ii-Electronics eziphathwayo:I-LCO (ubungakanani bubaluleke kakhulu)
Izithuthi zoMbane:I-NMC (ibhalansi yoluhlu kunye neendleko)
Ugcino lwamandla:I-LFP (ukhuseleko kunye nobomi obude)
Izixhobo zamandla:I-LMO (unikezelo lwamandla aphezulu)
Ukutshaja ngokukhawuleza:I-LTO (i-ultra{0}}ikhono lokutshaja ngokukhawuleza)
I-Aerospace/Umkhosi:I-NCA (ukusebenza okuphezulu)
Inyathelo lesi-3: Bala iiNdleko zoBunini zizonke
Sebenzisa ifomula enikelwe ngaphambili ukuthelekisa iindleko zokwenyani kubomi bebhetri, hayi amaxabiso angaphambili.
Inyathelo lesi-4: Vavanya iiMfuno zoKhuseleko
Qwalasela ukunyamezela kwakho umngcipheko kunye neemfuno zokhuseleko. Izicelo ezibalulekileyo kufuneka zibeke phambili i-LFP okanye i-LTO nangona iindleko eziphezulu okanye ukuxinwa kwamandla aphantsi.
Imibuzo ebuzwa qho
Loluphi uhlobo lwebhetri ye-lithium ion eqhelekileyo?
Iibhetri ze-NMCokwangoku zezona zixhaphakileyo ibhetri ye-lithium ion, ebambe malungaI-40% yesabelo semarike yehlabathi(marketsandmarkets.com). Zisetyenziswa kakhulu kwizithuthi zombane, izixhobo zombane, kunye neenkqubo zokugcina amandla ngenxa yeempawu zazo zokusebenza ezilungeleleneyo.
Zihlala ixesha elingakanani iintlobo zebhetri ye-lithium ion?
Ubomi bebhetri buhluka kakhulu ngokwekhemistri:
LTO:10-30 iminyaka (3,000-30,000 imijikelo)
I-LFP:5-15 iminyaka (1,000-9,000 imijikelo)
NMC:3-8 iminyaka (1,000-2,000 imijikelo)
I-LCO:2-5 iminyaka (500-1,000 imijikelo)
Obona bomi buxhomekeke kwiipateni zokusetyenziswa, ubushushu, kunye neendlela zokutshaja.
Loluphi uhlobo lwebhetri ye-lithium ion ekhuselekileyo?
LFP (Lithium Iron Phosphate)ithathwa njengolona hlobo lwebhetri ye-lithium ion ekhuselekileyo. Ine-aiqondo lobushushu le-thermal elibalekayo le-270 degreexa kuthelekiswa ne-LCO ye-150℃(greencubes.com), kwaye ayiyi kubamba umlilo naxa ihlatywe okanye yonakele. Iibhetri ze-LTO zikhuselekile ngokulinganayo kodwa zibiza kakhulu.
Zixabisa malini iintlobo zebhetri ye-lithium ion?
Amaxabiso emarike angoku (nge kWh):
LMO/LFP:$ 100-150 / kWh
NMC:$ 120-180 / kWh
I-LCO:$ 150-200 / kWh
NCA:$ 160-220 / kWh
LTO:$ 200-400 / kWh
Amaxabiso ehle kakhulu - into eluncedo{1}}isikali seebhetri zibiza ngaphantsi kwe $150/kWh ngo-2023, zehle ukusuka kwi-$1,400/kWh ngo-2010 (gminsights.com).
Loluphi uhlobo lwebhetri ye-lithium ion ebiza ngokukhawuleza?
LTO (Lithium Titanate)iibhetri zitshaja ngokukhawuleza, ziyakwaziI-10C + intlawulo yokubizakunye nokufikelela kwi-80% umthamo kwimizuzu nje emi-6. Nangona kunjalo, baneyona ndawo iphantsi yoxinano lwamandla. Phakathi kokhetho -luphezulu{5}}loxinzelelo,Iibhetri ze-NMCnikezela ngeyona nkonzo ikhawulezayo{0}}yokutshaja ukuya kuthi ga kwiireyithi ze-2C.
Loluphi uhlobo lwebhetri ye-lithium ion ilungileyo yokugcina ilanga?
iibhetri LFPzingcono kugcino lwamandla elanga ngenxa yazo:
Iprofayile yokhuseleko egqwesileyo(akukho mngcipheko womlilo)
Ubomi bomjikelo omde(6,{1}} imijikelo eqhelekileyo)
Iindleko eziphantsikubomi benkqubo
Ukunyamezela ubushushu obubanzi
Akukho cobalt(iinzuzo zokuziphatha kunye nokubonelela)
Abavelisi abakhulu bebhetri yelanga abanjengoTesla, Enphase, kunye neGenerac bonke basebenzisa ikhemikhali yeLFP kwiimveliso zabo zokugcina.
Ndazi njani ukuba loluphi uhlobo lwebhetri ye-lithium ion endinalo?
Jonga ileyibhile yebhetri okanye iinkcukacha zezalathi zekhemistri:
LiFePO4okanyeLFP= ILithium yentsimbi yePhosphate
Li-NMCokanyeNCM=Nickel Manganese Cobalt
Li-CookanyeI-LCO= ILithium Cobalt oxide
Li4Ti5O12okanyeLTO= ILithium Titanate
Unokwazi ukuchonga nge-voltage: iibhetri ze-LFP ziyi-3.2V yegama, ngelixa ezinye ezininzi ziyi-3.6-3.7V yegama.
Ngaba iintlobo zebhetri ye-lithium ion zinokuphinda zisetyenziswe?
Ewe, konkeiintlobo zebhetri ye-lithium ionziyarisayikilishwa, kodwa iinkqubo ziyahluka:
iibhetri LFPezona zilula ukuzisebenzisa kwakhona (akukho cobalt inetyhefu)
I-NMC kunye neLCOzifuna iinkqubo ezikhethekileyo zokubuyisela i-cobalt
iibhetri ze-LTOzine-titanium exabisekileyo ekufanele ukuba ibuyiselwe
Amazinga angoku okurisayikilisha asezantsi (5-10%) kodwa ayaphucuka ngokukhawuleza njengoko imimiselo iqina kunye nokuhambela phambili kobuchwepheshe.

