xhIsiXhosa saseMzantsi Afrika

Yintoni indlela yokusabela kwebhetri?

Nov 24, 2025

Shiya umyalezo

Yintoni indlela yokusabela kwebhetri?

Indlela yokusebenza kwebhetri

 

Okwangoku, akukho ukuqonda ngokuchanekileyo kunye nokuhambelana kwendlela yokusabela kwe-electrochemical ye-LiFePO₄ kwishishini. Ukusetyenziswa kweanion ehlanganisiweyo (PO₄)³⁻ kwenza intsimbi{1}}ikhompawundi esekwe ibe yimathiriyeli efanelekileyo yomgqatswa welithium{2}}icathodes yebhetri yeion. Nangona kunjalo, i-crystal structure ye-LiFePO₄ inciphisa ukuhanjiswa kwayo kunye ne-lithium -ukusebenza kwe-ion diffusion, okukhokelela ekunciphiseni kwe-electrochemical performance. Ngokungafaniyo nezixhobo zomaleko, ijiko lokukhupha iLiMPO₄ linethafa elithe tyaba, eliphawu oluqhelekileyo lwezigaba ezimbini zokusabela, okuthetha ukuba inkqubo yenguqu yesigaba phakathi kweLiMPO₄ kunye neMPO₄ yenzeka ngexesha le-lithium{8}}i-ion intercalation/deintercalation.

 

Imodeli yendlela yokusabela

 

I-LiFePO4 ifumana{1}}inqanaba lokuphendula ngamanyathelo amabini ngexesha lokutshaja nokukhupha ibhetri, okt.

 

Reaction mechanism model

 

 

Ngexesha lokutshaja, i-Li⁺ ifuduka kwi-FeO₆ layer, idlula kwi-electrolyte, kwaye ingene kwi-electrode engalunganga. I-Fe²⁺ i-oxidized ukuya kwi-Fe³⁺, ngelixa ii-electron zihamba ukusuka kwisekethe yangaphandle ukuya kwi-electrode engalunganga nge-ejenti yokunxibelelana kunye nomqokeleli wangoku. Inkqubo yokukhupha ibuyele umva.

 

Ukuchaza ezi zigaba zibini-zokuziphatha, uPadhi noGoodenough et al. Kuqale kwacetywa "core{2}}imodeli yeqokobhe," ebeka ukuba i-lithium{3}}i-ion intercalation/deintercalation process yenzeka kwiLiFePO₄/FePO₄ ezimbini{4}}ujongano lwesigaba, njengoko kubonisiwe kuMfanekiso 4-3a.

 

Ngexesha lokutshaja, i-interface ye-LiFePO₄/FePO₄ ngokuqhubekayo ihamba ukusuka kumphezulu ukuya embindini, ityhala ukuya kumbindi. I-Li⁺ iqhubekeka ifudukela ngaphandle, kwaye i-LiFePO₄ yangaphandle ihlala iguquka ibe yi-FePO₄. Ii-ion zeLithium kunye nee-electron ziqhubeka zidlula kwisigaba esitsha esenziwe{2}}sojongano lwesigaba ukugcina umsinga osebenzayo, kodwa i-lithium{3}}izinga lokusasazwa kwe-ion lihlala lihleli phantsi kweemeko ezithile. Njengoko i-interface phakathi kwezigaba ezibini iyancipha, ukusasazwa kwe-lithium ion ekugqibeleni kuya kuba nganelanga ukugcina i-current esebenzayo. I-LiFePO₄ kwi-particle core ayiyi kusetyenziswa ngokupheleleyo, okukhokelela ekulahlekelweni kwamandla. Emva kokuba ukutshaja kugqityiwe, i-LiFePO₄ engasetyenziswanga iya kuhlala phakathi kweqhekeza.

 

Ukuqwalasela ukuba i-lithium ion inokuthi idibanise kwaye idibanise kwiindawo ezininzi, uAndersson et al. icebise imodeli ye-mosaic ukuchaza ilahleko yesakhono sokuqala, njengoko kubonisiwe kuMfanekiso 4-3b. Imodeli ye-mosaic ibeka ukuba nangona i-lithium ion intercalation kunye nenkqubo ye-deintercalation ikwi-LiFePO₄/FePO₄ ezimbini - ujongano lwesigaba, inkqubo ingenzeka nakweyiphi na indawo ngaphakathi kweqhekeza. Ngethuba lokutshaja, ummandla we-FePO₄ wandisa kwiindawo ezahlukeneyo kwi-particle, kwaye imida yale mimandla idibanisa i-cross-contact, idala iindawo ezininzi ezifileyo ezingenakulungiswa, ngaloo ndlela kubangela ukulahlekelwa kwamandla. Ngexesha lokukhupha, ukusabela okubuyela umva kwenzeka, kunye ne-lithium ion ezidibanayo kwisigaba se-FePO₄. Inxalenye engundoqo apho i-lithium ion ingadityaniswanga ibangela ukulahleka kwamandla.

 

Figure 4-3 Lithium-ion intercalation/deintercalation model of lithium iron phosphate battery

 

 

Iimodeli ezimbini zethiyori zaphuhliswa ngaxeshanye, kodwa undoqo-imodeli yeqokobhe yamkelwa ngokubanzi ngabaphandi, nangona imathiriyeli ethile yeqokobhe kunye nondoqo zihlala ziphikisana. Ngokusekelwe kule mizekelo mibini, kunokugqitywa ukuba i-diffusion kinetics ye-lithium ion kunye nentlawulo zizinto ezithatha isigqibo sokusetyenziswa kwezinto eziphathekayo ze-electrode. Ekulungiseleleni izinto ze-lithium iron phosphate cathode, iinzame zenziwe zokufumana amaqhekeza amancinci kunye nobukhulu be-particle (nanoscale okanye i-microporous), usebenzisa i-carbon coating (ifilimu ye-nanocarbon) kunye ne-ion doping ukuphucula i-conductivity kunye ne-lithium ion diffusion.

 

Ngokuqonda okunzulu kwezixhobo ze-LiMPO, kwafunyaniswa ukuba le mizekelo mibini yayingahoywa iimpawu eziphezulu ze-anisotropic zothutho lwe-lithium ion kwizinto ze-LiMPO. I-Laffont icebise "iModeli yeqokobhe eNtsha-yokulungisa iziphene ze "core{2}}imodeli yeqokobhe." Ukwakha kule nto, i-Delmas yafunda iinqununu ze-LiFePO kwiindawo ezahlukeneyo zokunciphisa kwaye iphakamisa "i-Domino{4}} i-cascade Model," echaza ngokufanelekileyo ukuhlawula ngokukhawuleza kunye nokukhutshwa kokusebenza kwee-nanoscale particles, njengoko kuboniswe kwi-Figure 4-4.

Ngokuqonda okunzulu kwezixhobo ze-LiMPO, kwafunyaniswa ukuba le mizekelo mibini yayingahoywa iimpawu eziphezulu ze-anisotropic zothutho lwe-lithium ion kwizinto ze-LiMPO. I-Laffont icebise "iModeli yeqokobhe eNtsha-yokulungisa iziphene ze "core{2}}imodeli yeqokobhe." Ukwakha kule nto, i-Delmas yafunda iinqununu ze-LiFePO kwiindawo ezahlukeneyo zokunciphisa kwaye iphakamisa "i-Domino{4}} i-cascade Model," echaza ngokufanelekileyo ukuhlawula ngokukhawuleza kunye nokukhutshwa kokusebenza kwee-nanoscale particles, njengoko kuboniswe kwi-Figure 4-4.

 

Ngaphandle komahluko obalulekileyo phakathi kweemodeli ezikhankanywe ngasentla, owona mba ungundoqo ulele kuqikelelo kunye nokuchazwa kojongano lwezigaba ezimbini. Ekubeni i-kinetics yokufakwa kwe-lithium / ukukhutshwa kunye nokuguqulwa kwesigaba kuxhomekeke kakhulu kwi-particle size, i-morphology, kunye neempawu ze-physicochemical zezinto eziphathekayo, iingxoxo ezingentla (kubandakanywa neengxabano phakathi kweemodeli) zinokuba ngenxa yeemeko ezinganeleyo zokulinga.

Figure 4-4 Domino Model

Inkqubo yenguqu yenqanaba

 

Ngokuphuhliswa kwe-microscopy kunye ne-spectroscopy, ukuphendula kwesisombululo esiqinileyo kunye nezigaba eziphakathi ziye zabonwa kwaye zichongiwe ngexesha lokutshintshwa kwesigaba sezinto ze-LiMPO4, ezibonisa ukuba enye indlela yenguqu yesigaba ingaba khona kwizinto ze-LiMPO4. Kwiimpendulo zesisombululo esiluqilima, iiparamitha zeseli kunye nevolumu yeseli zibonisa utshintsho oluqhubekayo ngexesha lotshintsho lwesigaba. Ngokusebenzisa iimeko zokuvavanya ngokugqithiseleyo kunye neendlela zokulinganisa, ezifana ne-ultra-amasuntswana amancinci (nanoscale) kunye -nentlawulo ephezulu{6}}ukukhutshwa (ngaphezulu kwe-10C), iimpendulo eziqinileyo kunye nobukho bezigaba eziphakathi ziye zabonwa kwi-LiMPO4.

 

Isigaba sotshintsho ngexesha lokuhlawulisa{0}}iinkqubo zokukhupha kwiqondo lobushushu begumbi. Iibhetri zeLithium -zibonisa ukuguqulwa okuhle ngexesha lokuhlawuliswa{3}}kumjikelezo wokukhupha, onxulumene nokufana kwesakhiwo phakathi kwesigaba emva kwe-lithium{4}}i-ion deintercalation/intercalation. Ngexesha lokuhlawuliswa - kweenkqubo zokukhupha, ukubola kwamandla ebhetri kunxulumene ngokusondeleyo kwi-kinetics yenguqu yesigaba. Ngokwesakhiwo seLiFePO4, i [100]pmnb isalathiso sesona sithandwa kakhulu kwi-lithium -}yokufuduka kwe-ion, kwaye ujongano phakathi kwezigaba ezibini luhamba ecaleni kwe-c{11}}i-axis ngexesha lenkqubo{12}}yokukhupha.

 

(1) LiFePO₄/FePO₄The ratio of LiFePO₄/FePO₄ changes continuously with the battery charge-discharge reaction (the value of x in LiₓFePO₄ changes continuously). As lithium ions are extracted, the intensity of the diffraction peak produced by LiFePO₄ gradually decreases. When δ>I-0.2, i-peak ye-diffraction ye-Li₁₋δFePO₄ iqala ukunyamalala, kwaye ukuqina kwe-diffraction peak eveliswa yi-FePO₄ kancane kancane. Ngokwahlukileyo, njengoko i-lithium ion ifakwe, ubuninzi be-diffraction peak eveliswa yi-FePO₄ iyancipha ngokuthe ngcembe, kwaye ubuninzi be-diffraction peak eveliswa nguLi₁₋δFePO₄ inyuka ngokuthe ngcembe.

 

(2) LiₓFePO₄/Li₁₋yFePO₄I-LiₓFePO₄ kwiqondo lobushushu begumbi ngumxube we-Fe³⁺/Fe²⁺ exutywe{0}}i-valence mesophase LiₐFePO₄/Li₁₋ FePO₄. kwaye imele ukuxinana komthwali kunye nokutsiba-tsiba ngexesha lokutshaja nokukhupha, ngokulandelelanayo. I-powder neutron diffraction ibonise ukuba amaxabiso afanelekileyo kunye ne-0.05 kunye ne-0.11, ngokulandelanayo. Izinto ezinje nge-ion doping, ubushushu, inguqu yesinyithi, ubungakanani bamasuntswana, kunye-nobume bokungalingani ngokugqithisileyo zonke zichaphazela amaxabiso kunye. Ukonyusa amaxabiso kwaye kuya kuphucula ukusebenza kwekinetic ye-electrode reaction ngexesha lokutshaja kunye nokukhupha kwiqondo lobushushu begumbi.

 

3.Ubushushu kunye nokuhanjiswa kwesigaba

 

 

Kwi-450 degree, isisombululo esiqinileyo seLiₓFePO₄ sikhona, ngelixa kwiqondo lokushisa, izigaba ezimbini ze-metastable zikhona: Li₀.₇₅FePO₄ kunye neLi₀.₅FePO₄. Ngaphezulu kwe 500℃, iLiₓFePO₄ iqala ukubola ibe -ikhompawundi zeolivine; Ukwakhiwa kunye nomxholo wezi phosphates okanye iiphosfide zixhomekeke kwixabiso lika-x. Phakathi kwe-400 kunye ne-500 degree, kuphela isisombululo esiqinileyo seLiₓFePO₄ ekhoyo.

 

Utshintsho ngexesha lokupholisa lunzima kakhulu kunelo ngexesha lokufudumala. Ukubunjwa komxube ngexesha lokupholisa kuxhomekeke kwixabiso le-x kunye nenkqubo ye-thermal. Ekupholiseni, iLiₓFePO₄ ibolisa kuqala ibe ngumxube wezigaba ezimbini ezingezizo{2}}ze-olivine, umlinganiselo oxhomekeke kwixabiso lokuqala lobushushu kunye no-x. Xa iqondo lobushushu lingaphantsi (140±20 degree), ezimbini-inkqubo yesigaba iba yinkqubo entsonkothileyo, apho iLiFePO₄ kunye neFePO₄ zihlalisana nezinye ezimbini zeolivine{7}}iikhompawundi zodidi, iLiₓ₁FePO₄ kunye neLiₓ₂FePO₄. Ukuguga lo mxube kwiqondo lobushushu begumbi kubangela ukuba inkqubo yesigaba ezine{9}}iguquke kancinci ibe yinkqubo yesigaba seLiFePO₄ kunye neFePO₄.

 

Battery reaction mechanism

 

Ubume be-iron phosphate

 

 

I-FePO₄ ikho kwizakhiwo ezininzi: ① Emva kokuchithwa ngokupheleleyo kwe-LiFePO₄, i-orthorhombic FePO₄ iyayilwa; ② I-Triclinic FePO₄ ine-quartz{0}}efana nesakhiwo, kunye nazo zonke ii-cations tetrahedral ezilungelelanisiweyo; ③ I-Monoclinic kunye ne-orthorhombic FePO₄ inokulungiswa kwii-hydrates zazo. Zonke ezi ntlobo ze-crystalline ze-FePO₄, kunye ne-amorphous FePO₄, inokuguqulwa ibe yi-triclinic FePO₄ xa ifudumala.

 

Utshintsho ukusuka kwiLiFePO₄ ukuya kwi-FePO₄ lucotha kwaye aluphelelanga, kodwa lugqibeke xa ubushushu budlula i-500℃. Ngaphantsi kweemeko zokusebenza kwebhetri, izinto ze-cathode zizinzile ngokwe-kinetically. Ngexesha lokwenziwa kwe-LiFePO₄, kubalulekile ukuqinisekisa ukungabikho kwe-FePO₄. Ukuba ikhona, i-triclinic FePO₄ iyakwenziwa xa kufudunyezwa, okukhokelela kwisigaba seglasi esingasebenziyo{4}kwi-electrochemically active surface kumaqondo obushushu aphezulu.

 

Ion doping kunye conductivity

 

Ion doping inokuphucula ukuhanjiswa kwezinto. P-uhlobo lwemathiriyeli ye-semiconductor ene-conductivity efikelela kwi-10⁻² S/cm ifunyenwe nge-ion doping. I-Doping yinkqubo enzima kakhulu: kwelinye icala, izibalo ze-density functional theory (DFT) ze-electronic structure ye-LiFePO₄ phantsi kwe-local density approximation (LDA) kunye ne-generalized gradient approximation (GGA) ibonisa ukuba izinto eziphathekayo kufuneka zibonise iimpawu ze-metallic okanye i-semiconductor material, kunye nebhendi ye-conductor kunye ne-valence malunga ne-0 ephantsi ye-econductivity kunye ne-valence ephantsi kobubanzi be-eV. ngokwenene ibhaqwe. Kwelinye icala, ukuqwalasela intsebenziswano ye-electron orbitals kunye ne-Coulomb interactions emva kwe-ion doping, i-valence band structure inokwenzeka ngokwethiyori.

 

Izibalo ze-DFT ze-Mg- okanye i-Cr-i-doped LiFePO₄ zibonisa ukuba ubuninzi bobuninzi beemeko ze-elektroniki bubekwe kufutshane nenqanaba le-Fermi, elichaza i-metallic conductivity ye-doped material. Utshintsho kwi-conductivity ebangelwa yi-ion doping inokunxulumana nezi zinto zilandelayo:

 

I-1) Imida yemimandla ye-carrier carrier i-metallized.

I-2) Ion doping iyancipha ububanzi bebhendi ye-valence kunye nebhendi yokuqhuba.

I-3) Ukugqithisa ugxininiso oluthile olubalulekileyo, i-electron wavefunction ye-dopant ion ikhokelela ekubunjweni kwebhendi yokuqhuba.

4) Uhlobo, ugxininiso, kunye nokusabalalisa i-ion dopant.

5) Kuninzi lwe-M-Oksayidi zentsimbi, ibhendi yokuqhuba isinyithi ibonakala xa i-M{2}}M umgama webhondi ungaphantsi kwe-3 × 10⁻¹⁰ m.

I-6) Ngexesha lokudibanisa, ukongezwa kwekhabhoni ye-organic kubangela i-carbon coating yezinto, ukudala indlela esebenzayo yokuqhuba.

7) Ukubonakala kwe-Fe₂P. Ngexesha lokudibanisa, ukongezwa kwekhabhoni engaphezulu kunciphisa i-phosphate.

Ion doping and conductivity

8) Isibini se-Fe³⁺/Fe²⁺ redox sisebenza njenge-catalyst ekucuthweni kwe-LiFePO₄.

 

Impembelelo ye-Electrolyte

 

I-LiFePO₄ ibonisa ukuphinda kusebenze kunye ne-electrolyte edla ngokusetyenziswa. Indlela yokuziphatha ye-electrochemical yezinto ihambelana kakhulu kunye nekhemistry yayo yomhlaba ngaphakathi kwe-electrolyte. Ngokubanzi, ifilimu ye-passivation ifom kumphezulu wezinto eziphathekayo. Le filimu iququzelela i-lithium - ukusasazwa kwe-ion, inqanda ukulahleka kwezinto ezisebenzayo, kwaye kufuneka imelane nomthamo kunye nokutshintsha kwendawo ngexesha lokufakwa kwe-lithium- ion / ukukhutshwa. Iifilim zeCarbon{{6}ezigqunywe phezu kweLiFePO₄ zineekhompawundi ezifana neLiF, LiPF₆, LiₓFᵧ⁻, kunye neLiₓPOᵧFᶻ⁻.

 

I-electrolyte eqhelekileyo iqulethe i-alkyl carbonates kunye neetyuwa ze-lithium. Izinto ze-cathode zifumana iimpendulo ezininzi ezinokwenzeka kwi-electrolyte. Umzekelo, kwizisombululo ze-LiPF₆, i-asidi{2}}ye-reaction yesiseko phakathi kwe-LiFePO₄ kunye ne-trace amounts ye-HF ayinakuthintelwa. Ubukho be-HF kwi-electrolyte ineempembelelo ezimbini ezinobungozi: okokuqala, ukusabela kokutshintshwa phakathi kwe-iron ion kunye neeproton; kwaye okwesibini, ukusabela kwe-Li ions kunye ne-F ion kwi-particle surface ukwenza i-LiF, ethintela ukusabalalisa kwe-Li⁺.

 

Iiyoni ze-iron zinyibilika kwi-electrolytes. Uvavanyo lokunyibilika kwe-iron ion ye-LiFePO₄ kwii-electrolyte ezahlukeneyo luveze oku kulandelayo:

 

I-1) Kwii-electrolytes ezingenayo i-acidic contaminants, nakwiqondo lokushisa eliphakamileyo, ukuchithwa kwee-iron ion kunye nokulahlekelwa kwesisindo esibangelwayo kwezinto ezisebenzayo azinakwa.

2) I-asidi yesisombululo esiphezulu ikhokelela ekunyibilikeni kwe-iron ion lula.

3) Ubushushu obuphezulu bukhokelela ekunyibilikeni kwe-iron ion lula.

I-4) Umxholo ophezulu wekhabhoni ngaphakathi kwezinto eziphathekayo ubangela ukuzinza okukhulu kwezinto.

Indawo yoqhagamshelwano phakathi kwezinto ezisebenzayo kunye ne-binder ichaphazeleka kakhulu kwi-corrosion. Lo mhlwa unokuphetshwa ngokusebenzisa i-mesophase ye-alkaline okanye ukusebenzisa izongezelelo zokutshabalalisa ezimuncu. Kwiibhetri ze-lithium - ion usebenzisa i-LiFePO₄ njengesixhobo se-cathode, i-electrolyte engeyiyo{3}}eyi-acidic okanye i-carbon Ukongeza okanye i-coating ye-LiFePO₄ ingasetyenziselwa ukuthintela ukulahleka okukhulu.

 

Iimpawu ezinamandla

 

Iimpawu ze-kinetic ze-LiFePO₄ izinto ze-cathode azikaqondwa ngokupheleleyo. Ngokuqhelekileyo kukholelwa ukuba ubungakanani bamasuntswana kunye nokusabalalisa, i-conductivity, i-ion diffusion, i-kinetics ngexesha lokutshintsha kwesigaba (intlawulo{1}}inkqubo yokukhupha), kunye ne-carbon coating / doping zonke zichaphazela ukusebenza kwebhetri kwintlawulo eyahlukileyo{2}}izinga lokukhupha. I-carbon doping efanayo ithetha ukuba i-lithium ion kunye ne-electron ingafakwa kwaye ikhutshwe kwindawo efanayo kwizinto ezisebenzayo, ukunciphisa i-electrode polarization.

 

(1) Iimpembelelo zokuSebenza kwiZakhono Ukuqhuba okuphantsi kweLiFePO₄ esulungekileyo kukhokelela ngokuthe ngqo ekwehleni{1}}kwezinga eliphezulu lokukhupha umthamo webhetri. I-conductivity ye-LiFePO₄ ecocekileyo imalunga ne-10⁻⁹ S / cm, kwaye umthamo wokukhupha wehla ngokukhawuleza ukusuka kwi-148 mA·h / g kwizinga lokukhutshwa kwe-0.2C ukuya kwi-85 mA·h / g kwi-5C yokukhutshwa. Umthamo ophezulu wokukhutshwa kwezinto ze-cathode awusoloko unyuka ngokunyuka kwe-conductivity. Kwi-conductivity ephantsi, ukunyuka kwe-conductivity kuphucula i-electrochemical kinetics yezinto. Xa i-conductivity yezinto eziphathekayo idlula ixabiso elithile elibalulekileyo, i-conductivity ayisekho into yokumisela umthamo wezinga lezinto. I-LiFe₀.₉Ni₀.₁PO₄ (1.0 × 10⁻⁷ S/cm), kunye nokuqhuba kwayo okuphantsi, ibonisa amandla angcono aphezulu{17}}okukhutshwa kweqondo eliphezulu kune-LiFePO₄ (4.0 × 10⁻⁶ S/cm), ekhupha amandla kunye ne-5 mg/A 5·, 9/9 mh. ngokulandelanayo, kwizinga lokukhutshwa kwe-10C. Oku kuphakamisa ukuba i-lithium-i-ion diffusion inokuba ithathe indawo yokuqhuba njengeyona nto ibalulekileyo kwiipropathi ze-electrochemical ze-lithium{25}}ibhetri ze-ion.

 

2 Izinto zangaphandle ziquka ubungakanani bamasuntswana, ukusasazwa, kunye nemorphology. Imiba yangaphakathi ibhekisa ikakhulu kwi-lithium{5}}icoefficient yokusasazwa kweion. I-lithium -yeyoni yokusasazwa komlinganiso lixabiso elingaguqukiyo; amandla okusasazwa kwee-ion ze-lithium ayancipha ngokunyuka kwesayizi yamasuntswana kuba indlela yokusasazwa kwee-ion ze-lithium ngaphakathi kwesuntswana iyanda. Isakhono sokusasazwa kwee-ion ze-lithium sichanekile kwisikwere sobungakanani besuntswana kwaye sithelekiseka ngokuthe ngqo kwi-lithium-icoefficient yokusasazwa kweion. Ubungakanani besuntswana linempembelelo enkulu kwi-lithium{11}}yokusasazwa kwe-ion kune-coefficient yokusasazwa. Ubalo lwamanani lwe-lithium - ye-coefficient yokusasazwa kwe-ion kufuneka idityaniswe neendlela ezithile zokulinganisa kunye neemodeli zethiyori. Iindlela zokulinganisa eziphambili ziyi-galvanostatic titration (GITT) kunye ne-electrochemical impedance spectroscopy (EIS okanye i-AC Impedance).

 

3 Kwie-electrode zefilimu -ezincinci, ii-electron zingena kumqokeleli wangoku ngelixa ii-ion ze-lithium zingena kwi-electrolyte ukusuka kwelinye icala. Ngokuqulunqwa komgangatho we-FePO₄, ukuchasana nokunyakaza kwe-electron kuncipha, ngelixa ukuchasana kwe-lithium -intshukumo ye-ion kuyanda. I-FePO₄ kuqala i-nucleates kwiziphene zekristale kwaye emva koko ikhule macala onke, inqanda ukusasazwa kwe-lithium{8}}i-ion de i-lithium ion ingakwazi ukubaleka kwicala le- [100].

Thumela u kuphanda