Isikrabha sakho somgangatho sihamba emanzini, isicoci, kunye nekhemikhali etshiza ngalo lonke ixesha. Kodwa amandla ebhetri mhlawumbi avavanywa kuyo nayiphi na kwezi meko.
Isiqinisekiso se-IP67 nge-IEC 60529 nganye sigquma ukuntywiliselwa kwamanzi ahlaziyekileyo kwimitha enye imizuzu engamashumi amathathu. Ayivavanyi izicoci zealkaline, izicoci zeacidic, okanye ispike yokufuma emva koxinzelelo oluphezulu-lokuhlamba. Loo msantsa kulapho ukusilela kuqala khona, kodwa ipateni yezo ntsilelo ixhomekeke kwizinto eziguquguqukayo uninzi lwamaphepha aluchaziyo.


Yintoni "Imekobume emanzi" eneneni ithetha ngokuKhetha ibhetri
Ibhetri yescrubber emgangathweni ethelekelwe iimeko zokufuma ijonge ngaphezulu kwamanzi. Eyona nto isoyikiso yile nto inyibilikayo kuyo kwaye yintoni edada phezu kwayo.
Iikhemikhali zokucoca zorhwebo zenza umphunga ohlala kwii-terminals kunye nezindlu zokuxhuma. Kwiiveki ezininzi, le ntsalela yakha ifilimu eqhubayo ebangela ukukhutshwa okucothayo nokuba umatshini uhlala ungasebenzi. Iplanti enye yokulungisa ukutya sisebenze ngokulandelelwa ilahleko yexesha lokusebenza nge-18% kunyaka wokuqala ngokusebenzisa iilog ze-BMS. Unobangela yayingezizo iiseli{4}}ibiyintsalela yealkaline kwiziqhagamshelo zeAnderson, ikhawuleziswe sisitishi sokutshaja esibekwe kwindawo yokuhlambela. Olo hlobo lokusilela alubonakali nakweyiphi na iprotocol yovavanyo lwe-IP, yiyo loo nto umahluko omanzi-ochasene{7}}nokoma ngaphantsi kohlobo oluthile lokumanzi oluveliswa ngumsebenzi wakho.
Izigrogriso ezine zokufuma ezingabonisi kude kube lixesha lokudlala
Ukujiya ngaphakathi kweendawo ezivaliweyoiifom xa ukuguquka kweqondo lobushushu kungaphezulu koko kunokuphatha ibhetri. I-scrubber ehamba phakathi komgangatho wokuvelisa i-35 kunye ne-closet yokutshaja i-15℃iya kuphuhlisa ukufuma kwangaphakathi ekuhambeni kwexesha. Obo bumanzi bufumana indlela yokuya kwiindawo zokuqhagamshela kwaye umonakalo uqokelelana ngokungabonakali de ikhowudi yempazamo ye-BMS ifikelele kumphezulu.
Inkungu yekhemikhali evela kwidekhi yebrashiKunzima ukukuphepha kunokutshiza ngokuthe ngqo. Ihlala kuwo wonke umphezulu ovelileyo ngaphakathi kwemitha, kuqukwa neendawo zokuphola zebhetri. I-oxidation yetheminali yonyusa ukuchasana nokunxibelelana, kwaye ukutshaja kwangoku kuyehla ngaphambi kokuba nabani na abone uphawu.
Iindawo zokutshaja-eziphakamileyo zokufumadibanisa zombini iziphumo. I-Lead{{1}i-asidi ivaliwe{2}}igesi edityaniswe nokufuma okukwindawo engqongileyo ikhawulezisa ukubola kwetheminali ngokukhawuleza kunokusebenza kwesiqhelo kuphela. Iipakethe zeLithium zithintela ingxaki yehydrogen kodwa zijongane ne-BMS sensor drift xa ukufuma kogcino kuhlala kudlula i-60%. Siye sabona ukufundwa kobushushu kutshintsha nge-3-4℃kwezi meko, ngokwaneleyo ukuqalisa ukunqunyulwa kwentlawulo kwangaphambi kwexesha.
Ithuba lokutshaja ngexesha lekhefuibetha ilothe ezele zizikhukula{0}kakhulu ngeasidi. I-Electrolyte stratification kunye nokufuma{2}}ukucutha umhlwa oqhutywa kulindelwe ubude bobomi ngokumalunga nesiqingatha xa kuthelekiswa{3}}nokutshaja komjikelo ogcweleyo kwisithuba semozulu{4}elawulwayo.

Okusingqongileyo{0}}Ukhetho lokuqala: Iimeko ezine
Isitora esomileyo esinobushushu obuzinzileyo kunye nendawo ezinikeleyo yokutshaja.Ilothe ekhukulayo{0}iasidi ihlala inexabiso{1}}isebenza apha. Ukufuma okungaphantsi kwe-50%, ukutyhileka kwikhemikhali okuncinci, kunye nesithuba sendlela zogcino olululo luthetha ukuba ungalindela ubomi bomjikelo opapashiweyo{4}}ngokwesiqhelo 3{7}}iminyaka emi-5 ngokujongwa kwamanzi ngeveki. Le kuphela kwemeko apho uqoqosho lweeseli ezimanzi lusasebenza.
Ukulungiswa kokutya okanye ikhitshi yorhwebo ifuna ikhemistri etywiniweyo.Izixhobo zokucoca ialkaline kunye nokuhlanjwa kwemihla ngemihla kudala iivektha ezininzi zokuthosa kwiibhetri ezikhukulayo. Iipakethe ze-LiFePO4 ezine-IP67 ezivaliweyo zibamba ukufuma; umbuzo ngowokuba ngaba ukuxhathisa kwamachiza kwavavanywa ngenene. Cela umthengisi ngetyuwa-isitshizi okanye ikhemikhali-iziphumo zovavanyo lokuba sesichengeni{6}}uvavanyo oluqhelekileyo lwe-IP aluquki.Iipakethi zokukhuhla phantsi kwePolinovelsebenzisa i-IP67-izindlu ezireyithiweyo ezineepoxy{2}}iitheminali ezitywiniweyo, eziyilelwe ngokukodwa iindawo zokucoca ukufuma okuphezulu. Ukucwangciswa kwe-24V 100Ah kuhambelana neTennant T7 kunye neNilfisk BR755 amagumbi ngaphandle kokuguqulwa.
Amaziko okhathalelo lwempilo ajongene nesinyanzelo esahlukileyo: ukuba sesichengeni ngesibulali-ntsholongwane kunye nokungaphelelwa lixesha.Unyamezelo lweLithium ekubizeni{0}karhulumente ngokuyinxenye kuyabaluleka kuba ukutshaja kwamathuba kudla ngokuba yeyona festile yenyani. Ilothe ekhukulayo -i-asidi sulfates ngokukhawuleza phantsi kwaloo pateni, kwaye iAGM iyiphatha ngcono kancinci. Beka phambili iipakethi nge-BMS{4}}inqanaba lobushushu kunye nokugawulwa kokufuma; ukuba idatha ibamba iingxaki kwiiveki ngaphambi kokuba ukwehla kwexesha lokubaleka kubonakale.
Ugcino olubandayo longeza{0}}izithintelo zokutshaja ubushushu obuphantsi ngaphezulu komngcipheko wokuxinana.Self - ukufudumeza iimodyuli ze-lithium zigcina ukwamkelwa kwentlawulo ngaphantsi - kwe-20℃, kodwa ingxaki ye-condensation ngexesha lotshintsho lwezowuni yahlukile. Ipakethi yebhajethi ye-lithium ngaphandle kolawulo lobushushu iyasilela apha ngokukhawuleza kuneAGM echazwe ngokufanelekileyo. Ukuba umsebenzi wetsheyini obandayo-yeyona nto iphambili, qinisekisa ukuba ipakethe ibandakanya zombini{6}}ukufudumeza kunye ne-conformal{8}}zangaphakathi ezigqunyiweyo. I-Polinovel inikezela ngokusebenza ngokuzifudumeza ngaphantsi kwe-10℃njengesiqhelo kwi-series ye-36V.
Kumsebenzi othatha iindidi ezininzi zemeko-bume{0}thi, idokhi efumana indawo ekufutshane kunye nogcino olukwifriji{1}}siqhele ukuqwalasela iinkqubo zombane ezixubeneyo nemekobume{2}}imida ye-BMS ethile.Qhagamshelana neqela lethu lobunjinelingobeko loncedo kwaye sinokuqinisekisa ukuba uhlobo lwepakethi enye lugquma uluhlu lwakho okanye ukuba izowuni{0}}ubumbeko oluthile lwenza ingqiqo ngakumbi.

Ingxaki yesiKhululo sokuTjaja Akukho mntu uVavanyayo ekuThengweni
Ukusilela kwebhetri okuninzi okutyholwa kwiiseli ezineziphene kubuyela emva kwiimeko zokutshaja.
Umxhasi olungisa inyama osebenzisa i-Tennant T7s ulandele i-14-yenyanga engumndilili wobomi bebhetri{4}}isiqingatha sobude obulindelweyo. Siye safudusa isikhululo sabo sokutshaja ukusuka kwindawo yokuhlambela-ekufuphi negumbi lokuhlamba ukuya kwipaseji yokulungisa umoya kwi-Q{5}} iilog ze-BMS ukuya ekupheleni kuka-2024 zibonise kwaloo pakethi zebhetri zinye zisabambe ngaphezulu kwe-85% umthamo kwiinyanga ezingama-28, kungekho tshintsho kwikhemistri kwaye kungekho nolunye uhlengahlengiso lokusebenza.
Ulungiso longeza iindleko: mhlawumbi ukuhambisa isiseko sokutshaja, okanye uchaze iibhetri ezinoyilo lwetheminali evalwe ngokupheleleyo kunye neebhodi ze-BMS{0}ezigqunywe ngokusesikweni.Iipakethi ze-Polinovel ze-LiFePO4zibandakanya zombini iimpawu njengemigangatho kwimodeli ezibekwe kukutya{0}}nokusasazwa kwishishini.
I-BMS njengeSixokelelwano sakho saKwangoko
Multi{0}inqaku lokujongwa kweqondo lobushushu iflegi yokungena kokufuma phambi kokuba ilahleko yesakhono ibe nokulinganiswa. I-Bluetooth{2}}iipakethi ezenziweyo zivumela ukuhamba okukude kuzo zonke iinqwelo ezisasaziweyo ngaphandle kokutsala oomatshini ngaphandle kweintanethi. Umahluko wobushushu kumjikelo wentlawulo ngumqondiso; ukuyibamba kwangethuba kuphepha ixesha lokwehla elingacwangciswanga.
Ayizizo zonke iinkqubo ze-BMS ezibonelela ngokubonakala. Ungeno-iipakethi ze-lithium zihlala zibandakanya ukhuseleko{2}}kuphela i-BMS ngaphandle komsebenzisi{3}}uxilongo olufikelelekayo. Kumanzi-izithuthi zokukhuhla okusingqongileyo, loo msantsa uthetha ukuba iingxaki zihlala zifihliwe de ixesha lokubaleka lehle ngokubonakalayo. Xa uchaza iipakethi zokuvezwa kweekhemikhali okanye ukufuma okungaphezulu kwe-60%, qinisekisa ukuba i-BMS ibonelela nge{8}}ixesha lokwenyani lokubeka iliso, hayi nje ukunqanda ukhuseleko.
IiNkcazelo zeBattery yokuCoca umgangatho wePolinovel
I-Polinovel ivelisaIinkqubo zebhetri ye-LiFePO4 kwi-24V kunye ne-36V yoqwalaseloukuhamba-umva kwaye ukhwele-kwizikhuseli zomgangatho, ngokuhambelana okuqinisekisiweyo ngapha kweTennant T7/T12, Nilfisk BR755/SC6000, Kärcher BR 65/90, kunye namanye amaqonga eOEM amakhulu.
Umgangatho -umgca wokucoca uphethe isatifikethi sezothutho se-UN38.3, ukumakishwa kwe-CE, kunye nokuthotyelwa kwe-IEC 62619 kugcino lwamandla oshishino. Iindawo ezivalekileyo ze-IP67 ziyavavanywa ngokwe-IEC 60529 ngetyuwa eyongezelelweyo{6}}isiqinisekiso sesitshizi sokutya{7}}kusetyenziso lweshishini. Ixesha eliqhelekileyo lokukhokela liqhuba iiveki ze-3-4 zokucwangciswa kwempahla;indawo ebiyelweyo yesiko okanye uhlengahlengiso lwesinxibelelanisiyongeza iiveki ezi-2.
Amaxabiso ayahluka ngokomthamo kunye noqwalaselo. Njengendawo yesalathiso, i-24V 150Ah ipakethe iqhuba i-2.5 - 3x ixabiso elingaphambili le-asidi elinganayo yesikhukula -, kunye ne-TCO yenzeke phakathi kweenyanga ze-18-24 ngokuxhomekeke ekuhlawulisweni kweziseko zophuhliso kunye namazinga okugcinwa kwabasebenzi. Singabonelela ngothelekiso lwe-TCO oluthe ngqo kwisiza ukuba wabelana ngamaza okutshintsha kwebhetri yakho yangoku kunye neengqikelelo zeendleko zomsebenzi.
Inyathelo elilandelayo:Qhagamshelana neqela lobuchwephesha lePolinovel ngeprofayile yakho yoncedo{0}}uhlobo lokusingqongileyo, imodeli yesixhobo sangoku, kunye nokumisela ukutshaja. Siza kubonelela ngengcebiso yemveliso ehambelanayo kwaye, apho kufanelekileyo, idatha yereferensi evela kukusasazwa okufanayo.

